  preliminary specification model dc voltage output setup, rise time hold up time (typ.) voltage range note.5 frequency range power factor efficiency(typ.) ac current (typ.) input inrush current (typ.) leakage current safety standards working temp. working humidity storage temp., humidity temp. coefficient vibration mtbf dimension others note packing overload 1500ms, 50ms/230vac 1500ms, 50ms/115vac at full load 16ms/230vac 16ms/115vac at full load 90 ~ 264vac 127 ~ 370vdc 47 ~ 63hz pf 0.95/230vac pf 0.97/115vac at full load 12a/115vac 6a/230vac cold start 25a/115vac 40a/230vac 105 ~ 135% rated output power -20 ~ +70 (refer to output load derating curve) 20 ~ 90% rh non-condensing -40 ~ +85 , 10 ~ 95% rh 0.03%/ (0 ~ 45 ) 10 ~ 500hz, 5g 10min./1cycle, period for 60min. each along x, y, z axes over voltage ripple & noise (max.) note.2 voltage adj. range remote programming (pv) voltage tolerance note.3 environment protection 1. all parameters not specially mentioned are measured at 230vac input, r ated load and 25 of ambient temperature. 2. ripple & noise are measured at 20mhz of bandwidth by using a 12" twisted pair- wire terminated with a 0.1uf & 47uf parallel capacitor. 3. tolerance : includes set up tolerance, line regulation and load regula tion. 4. the power supply is considered a component which will be installed into a fi nal equipment. the final equipment must be re-confirmed that it still mee ts emc directives. 5. derating may be needed under low input voltage. please check the deratin g curve for more details. ch1, ch2 : protection type : shut down o/p voltage, re-power on to recover ch3, ch4 : protection type : constant current limiting, unit will shut down a fter 3 sec., re-power on to recover protection type : shut down o/p voltage, re-power on to recover line regulation load regulation ch1 output number features : universal ac input / full range protections: short circuit / overload / over voltage/over temperatu re forced air cooling by built-in dc fan built-in remote on-off function for ch3,ch4 and the whole unit isolate output built-in remote sense function(ch3,ch4) built-in external voltage control function(ch3,ch4) built-in output current monitor signal(ch3,ch4) ac input active surge current limiting built-in active pfc function, pf>0.95 1000w quad output power supply 278*177.8*63.5mm (l*w*h) i/p-o/p, i/p-fg, o/p-fg:100m ohms/500vdc / 25 / 70% rh design refer to ul60950-1,tuv en60950-1 i/p-o/p:3kvac i/p-fg:1.5kvac o/p-fg:0.5kvac withstand voltage isolation resistance k hrs min. mil-hdbk-217f (25 ) kg qp-1000 ch3 ch4 ch2 130.8w(max.) 1000w(max.) 86% 30 ~ 34.8v 13.8 ~ 16.2v 30~ 34.8v 5.75 ~ 6.75v <2ma / 240vac rated current current range rated power (convection) remote control current monitor rc+/rc-: short , power on ; rc+/rc-: open , power off signal provides an output of 0 ~ 5v which applies over 10 ~ 100% of rated load. function over temperature protection type : shut down o/p voltage, recovers automatically after t emperature goes down turn on/off ch3,ch4 and the whole power supply 75 5 detect on heatsink of power transistors 12v 5v 24v 24v 25a 12.5a 8.4a 6a 0 ~ 25a 600w 0 ~ 12.5a 300w 0 ~ 8.4a 0 ~ 6a 120mvp-p10.8 ~ 13.2v ch3,ch4 10% ~ 120% adjustable by 0.5 ~ 6vdc external control 80mvp-p4.5 ~ 5.5v 100mvp-p21.5 ~ 26.5v 200mvp-p 21.5 ~ 26.5v 2.0% 2.0% 1.0% 0.5% 0.5% 0.5% 1.0% 1.0% 1.0% 1.0% 0.5% 1.0% q p - 1 0 0 0 harmonic current ems immunity compliance to en55022 (cispr22) compliance to en61000-3-2,-3 compliance to en55024, en61000-6-2, en61204-3 en61000-4-2,3,4,5,6,8,11; env50204, emi conduction & radiation safety & emc (note 4) output voltage external control please see the function manual file name:qp-1000-spec 2008-12-05
preliminary mechanical specification file name:qp-1000-spec 2008-12-05 case no. unit:mm pin no. 2 1 3,4 +rc : +remote of/off vcc : 12v/0.1a auxiliary output for remote control assignment +rc vcc com mating housing terminal or equivalent or equivalent control pin no. assignment(cn2): hrs df11-4dp-2ds or equivalent hrs df11-4ds hrs df11-**sc ac input terminal pin no. assignment (tb1) pin no. 13 2 assignment ac/n ac/l dc output terminal pin no. assignment (tb2) pin no. pin no. 1,2 8 7 3,4 9 5 10 6 assignment assignment +v4 +v2 -v2 -v4 +v3 +v1 -v3 -v1 pin no. pin no. pin no. pin no. 22 11 33 44 +s : +remote sensing pv : voltage control -s : -remote sensing im : output current monitor +rc : +remote of/off g : gnd ps : reference voltage terminal +s : +remote sensing pv : voltage control -s : -remote sensing im : output current monitor +rc : +remote of/off g : gnd ps : reference voltage terminal assignment assignment assignment assignment -s -s +s +s +rc +rc ps ps mating housingmating housing terminal terminal or equivalent or equivalent or equivalent or equivalent 66 55 pv pv im im control pin no. assignment(cn1) for ch3: hrs df11-8dp-2ds or equiva lent control pin no. assignment(cn3) for ch4: hrs df11-8dp-2ds or equiva lent hrs df11-8ds hrs df11-8ds hrs df11-**sc hrs df11-**sc 7,8 7,8 gg fg 1 1 2 2 3 4 5 6 7 8 9 10 cn3 cn2 cn1 tb2 tb1 + adj adj adj1 adj2 led led led led + + + 1 1 12 34 2 2 7 7 8 8 3 direction air flow 18 63.5 38 12.5 245 278 8-m4(both sides) l=8mm 4-m4 l=5mm 16max. 13max. 18 7.9 162 11 10 13 245 9 q p - 1 0 0 0 1000w quad output power supply
preliminary file name:qp-1000-spec 2008-12-05 circuit detection emi filter rectifiers pfc & pfc control power power power pwm pwm pwm switching switching switching control control control filter filter filter filter control control && && && rectifiers rectifiers rectifiers rectifiers ma ma +v3 +v4 -v4 +v1 +v2 -v1 -v2 -v3 i/p fg o.v.p. o.v.p. o.l.p. o.l.p. o.l.p. o.t.p aux power fan aux power 12v/0.1a control remote circuit detection control remote rc(v3) +s -s -s +s rc(v4) filter & rectifiers rc control remote q p - 1 0 0 0 1000w quad output power supply block diagram output derating vs input voltage input voltage (vac) 60hz 90 100 95 120 115 160 140 200 180 240 220 264 load (%) ta=25 90 100 80 70 60 50 40 load (%) ambient temperature ( ) derating curve (horizontal) -20 0 10 20 30 40 50 60 70 20 40 50 60 80 100 o.v.p. o.v.p.
preliminary 1.remote on/off the psu by using the "remote on/off" function a. for ch3 (cn1) or ch4 (cn3) b. for ch1 ~ ch4 (cn2) between +rc(pin3) and g(pin7,8) between +rc(pin1) and com(pin2,4) sw on (short) sw on (short) sw off (open) sw off (open) output status output status on on off off +rc +rc g com sw sw 2.external voltage control by ch3,ch4 1 2 3 4 5 6 v vout 100 120 40 60 80 20 output voltage (%) external voltage (dc) non-linear 40 60 80 100 120 v 100 40 60 80 20 output current (%) output voltage (%) 20 +s +v +v -v load -v -s pv 1~6v -s function manual file name:qp-1000-spec 2008-12-05 q p - 1 0 0 0 quad output power supply


▲Up To Search▲   

 
Price & Availability of QP-100009

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X